A Python driver for the Watlow EZ-Zone PM temperature controller standard bus protocol
- Free software: GNU Lesser General Public License v3 (LGPLv3)
Installation¶
pip install pywatlow
You can also install the in-development version with:
pip install https://github.com/BrendanSweeny/pywatlow/archive/master.zip
Documentation¶
Development¶
To run the all tests run:
tox
Note, to combine the coverage data from all the tox environments run:
Windows | set PYTEST_ADDOPTS=--cov-append
tox
|
---|---|
Other | PYTEST_ADDOPTS=--cov-append tox
|
Usage¶
Command Line Usage¶
Format:
pywatlow [-h] [-r PORT ADDR PARAM | -s PORT ADDR TEMP]
Read the current temperature in degrees Celsius. This is equivalent to calling Watlow(port=’COM5’,address=1).read():
# Read the current temperature (parameter 4001) of the Watlow controller
# at address 1 (Watlow controller's default) on serial port COM5:
>>> pywatlow -r COM5 1 4001
{'address': 1, 'param': 4001, 'data': 50.5, 'error': None}
Read the setpoint temperature in degrees Celsius. This is equivalent to calling Watlow(port=’COM5’,address=1).readSetpoint():
# Read the setpoint (parameter 7001) of the Watlow controller
# at address 1 on serial port COM5:
>>> pywatlow -r COM5 1 7001
{'address': 1, 'data': 60.0, 'error': None}
Change the setpoint temperature (degrees Celsius). This is equivalent to calling Watlow(port=’COM5’,address=1).write(50):
# Change the setpoint of the Watlow controller
# at address 1 on serial port COM5:
>>> pywatlow -w COM5 1 60
{'address': 1, 'param': 7001, 'data': 60.0, 'error': None}
At this time, CLI usage only supports reading the current temperature and the current setpoint.
Module Usage¶
To use pywatlow in a project:
from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)
print(watlow.read())
print(watlow.readSetpoint())
print(watlow.write(55))
##### Returns #####
{'address': 1, 'param': 4001, 'data': 59.5, 'error': None}
{'address': 1, 'param': 7001, 'data': 60.0, 'error': None}
{'address': 1, 'param': 7001, 'data': 55.0, 'error': None}
Using multiple temperature controllers on a single USB to RS485 converter:
from pywatlow.watlow import Watlow
import serial
ser = serial.Serial()
ser.port = 'COM5'
ser.baudrate = 38400 # Default baudrate for Watlow controllers
ser.timeout = 0.5
ser.open()
watlow_one = Watlow(serial=ser, address=1)
watlow_two = Watlow(serial=ser, address=2)
print(watlow_one.read())
print(watlow_two.read())
##### Returns #####
{'address': 1, 'param': 4001, 'data': 50.5, 'error': None}
{'address': 2, 'param': 4001, 'data': 60.0, 'error': None}
Reading Other Parameters¶
See the Watlow user manual for more information about the different parameter IDs and their functions.
The messaging structure for Watlow temperature controllers is set up to return data as integers or floats depending on the nature of the data. Often, ints are used to represent a state, such as in parameter ID 8003, the control loop heat algorithm.
data_type is not optional. Passing the incorrect type to data_type may result in an error (e.g. watlow.readParam(7001, int)). To see which data type each parameter expects, see the Watlow user manual.
In some cases, specifying the wrong data type (e.g. watlow.readParam(8003, float)) will result in the instance of Watlow reading characters from a separate queued message if multiple controllers are being used on the same USB/RS485 port without any async handling.
Here, a returned value of 71 for parameter 8003 corresponds to the PID algorithm. We can read the state of 8003 like so:
from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)
# Read the current heat algorithm
print(watlow.readParam(8003, int))
# Errors:
# Here the incorrect data type is given
print(watlow.readParam(7001, int))
##### Returns #####
{'address': 1, 'param': 8003, 'data': 71, 'error': None} # 71 --> PID algorithm
If the user wishes to avoid parameters altogether, basic functionality (read temp/setpoint and write temperature) can be achieved with wrapper functions read(), readSetpoint(), and write(), described above. Other parameters can be set at the controllers using the physical buttons and hardware menu.
Setting Other Parameters¶
watlow.writeParam() is used to write to specific Watlow parameters. The message structure required for the set request depends on the data type (int or float). pywatlow will build the message based on this data type, which can be specified by passing the type class (either int or float) to the data_type argument.
If instead of a PID algorithm we would like something relatively simple like an “on-off” algorithm, we can set the value of parameter 8003 to 64:
from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)
print(watlow.readParam(8003, int))
print(watlow.writeParam(8003, 64, int))
print(watlow.writeParam(8003, 71, int))
# Errors:
# Here the incorrect data type is given
print(watlow.writeParam(8003, 71, float))
##### Returns #####
{'address': 1, 'param': 8003, 'data': 71, 'error': None} # 71 --> PID algorithm
{'address': 1, 'param': 8003, 'data': 64, 'error': None} # 64 --> on/off algorithm
{'address': 1, 'param': 8003, 'data': 71, 'error': None} # Back to 71, PID
# Error resulting from specifying the wrong data type:
{'address': 1, 'param': None, 'data': None, 'error': Exception('Received a message that could not be parsed from address 1')}
Error Handling¶
Errors are passed through using the ‘error’ key of the returned dictionary. Here there is no temperature controller at address 2:
print(watlow_one.read())
print(watlow_two.read())
##### Returns #####
{'address': 1, 'param': 4001, 'data': 55.0, 'error': None}
{'address': 2, 'param': None, 'data': None, 'error': Exception('Exception: No response at address 2')}
Reference¶
Watlow¶
-
class
watlow.
Watlow
(serial=None, port=None, timeout=0.5, address=1)[source]¶ Object representing a Watlow PID temperature controller. This class facilitates the generation and parsing of BACnet TP/MS messages to and from Watlow temperature controllers.
- serial: serial object (see pySerial’s serial.Serial class) or None
- port (str): string representing the serial port or None
- timeout (float): Read timeout value in seconds
- address (int): Watlow controller address (found in the setup menu). Acceptable values are 1 through 16.
timeout and port are not necessary if a serial object was already passed with those arguments. The baudrate for Watlow temperature controllers is 38400 and hardcoded.
-
read
()[source]¶ Reads the current temperature. This is a wrapper around readParam() and is equivalent to readParam(4001, float).
Returns a dict containing the response data, parameter ID, and address.
-
readParam
(param, data_type)[source]¶ Takes a parameter and writes data to the watlow controller at object’s internal address. Using this function requires knowing the data type for the parameter (int or float). See the Watlow user manual for individual parameters and the Usage section of these docs.
- param: a four digit integer corresponding to a Watlow parameter (e.g. 4001, 7001)
- data_type: the Python type representing the data value type (i.e. int or float)
data_type is used to determine how many characters to read following the controller’s response. If int is passed when the data type should be float, it will not read the entire message and will throw an error. If float is passed when it should be int, it will timeout, possibly reading correctly. If multiple instances of Watlow() are using the same serial port for different controllers it will read too many characters. It is best to be completely sure which data type is being used by each parameter (int or float).
Returns a dict containing the response data, parameter ID, and address.
-
readSetpoint
()[source]¶ Reads the current setpoint. This is a wrapper around readParam() and is equivalent to readParam(7001, float).
Returns a dict containing the response data, parameter ID, and address.
-
write
(value)[source]¶ Changes the watlow temperature setpoint. Takes a value (in degrees F by default), builds request, writes to watlow, receives and returns response object.
- value: an int or float representing the new target setpoint in degrees F by default
This is a wrapper around writeParam() and is equivalent to writeParam(7001, value, float).
Returns a dict containing the response data, parameter ID, and address.
-
writeParam
(param, value, data_type)[source]¶ Changes the value of the passed watlow parameter ID. Using this function requires knowing the data type for the parameter (int or float). See the Watlow user manual for individual parameters and the Usage section of these docs.
- value: an int or float representing the new target setpoint in degrees F by default
- data_type: the Python type representing the data value type (i.e. int or float)
data_type is used to determine how the BACnet TP/MS message will be constructed and how many serial characters to read following the controller’s response.
Returns a dict containing the response data, parameter ID, and address.
Watlow Messaging Structure¶
The following is an incomplete understanding of the messaging structure that the Watlow temperature controllers use. Enough of the structure is understood for the driver to be functional, but the function of many of the bytes is unknown to the author(s).
General Message Structure:
- BACnet MS/TP protocol
- First two bytes of any message make up the preamble, and are always: 55 FF
- Byte 3 seems to define the type of message (read/response)
- Byte 4 of the request defines the zone (internal Watlow address)
- The zone appears in byte 5 of the response
- Byte 7 appears to define the type of request
- Byte 8 is the header check byte (more info at reverseengineering.stackexchange.com)
- Immediately following the parameter bytes is the instance. I have yet to encounter a situation where this is not 01
- The final two bytes of any message are the data check bytes (more info at reverseengineering.stackexchange.com)
How to read the example message tables:
- Addr.: The address used in the request and response
- Param: The parameter being read/set
- Process Val.: The value represented in the “Data” column of the response/request
- The message begins with the column labeled “Preamble” and continues to the right
- Sometimes the byte number is not the same in the response as the request (e.g. Zone), hence the “-“
Read Requests¶
- Read requests seem to be 16 bytes long no matter the data type
- Byte 7 is 06 for read requests
- Bytes 12 and 13 represent the parameter to be read
- Byte 14 is the instance, generally 01
Where the response is a float:¶
- Request is 16 bytes long
- Response is 21 bytes long
- Response types appear to be defined by bytes 7
- Note: The process value for 4001 is ~2500 in these examples because no probe is connected
Addr. | Param | Process Val | Preamble | Req/Res | ?? | Zone | ?? | ?? | ?? | Chk | ?? | Param | Instance | ?? | Data | Data Chk |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 4001 | – | 55 FF | 05 | – | 10 | 00 | 00 | 06 | E8 | 01 03 01 | 04 01 | 01 | – | – | E3 99 |
2529.6 | 55 FF | 06 | 00 | 10 | – | 00 | 0B | 88 | 02 03 01 | 04 01 | 01 | 08 | 45 1E 3C D4 | A7 28 | ||
2 | 4001 | – | 55 FF | 05 | – | 11 | 00 | 00 | 06 | 61 | 01 03 01 | 04 01 | 01 | – | – | E3 99 |
2528.7 | 55 FF | 06 | 00 | 11 | – | 00 | 0B | 10 | 02 03 01 | 04 01 | 01 | 08 | 45 1E 0C 06 | 9A 6B | ||
1 | 4012 | – | 55 FF | 05 | – | 10 | 00 | 00 | 06 | E8 | 01 03 01 | 04 0C | 01 | – | – | 9B 29 |
0.0 | 55 FF | 06 | 00 | 10 | – | 00 | 0B | 88 | 02 03 01 | 04 0C | 01 | 08 | 00 00 00 00 | 2D 64 | ||
2 | 4012 | – | 55 FF | 05 | – | 11 | 00 | 00 | 06 | 61 | 01 03 01 | 04 0C | 01 | – | – | 9B 29 |
0.0 | 55 FF | 06 | 00 | 11 | – | 00 | 0B | 10 | 02 03 01 | 04 0C | 01 | 08 | 00 00 00 00 | 2D 64 | ||
1 | 7001 | – | 55 FF | 05 | – | 10 | 00 | 00 | 06 | E8 | 01 03 01 | 07 01 | 01 | – | – | 87 76 |
392.0 | 55 FF | 06 | 00 | 10 | – | 00 | 0B | 88 | 02 03 01 | 07 01 | 01 | 08 | 43 C4 00 00 | 33 9A | ||
Where the response is an integer:¶
- Request is 16 bytes long
- Response is 20 bytes long
Addr. | Param | Process Val | Preamble | Req/Res | ?? | Zone | ?? | ?? | ?? | Chk | ?? | Param | Instance | ?? | Data | Data Chk |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 8003 | – | 55 FF | 05 | – | 10 | 00 | 00 | 06 | E8 | 01 03 01 | 08 03 | 01 | – | – | F0 0F |
71 | 55 FF | 06 | 00 | 10 | – | 00 | 0A | 76 | 02 03 01 | 08 03 | 01 | 0F 01 | 00 47 | C5 6B | ||
2 | 8003 | – | 55 FF | 05 | – | 11 | 00 | 00 | 06 | 61 | 01 03 01 | 08 03 | 01 | – | – | F0 0F |
71 | 55 FF | 06 | 00 | 11 | – | 00 | 0A | EE | 02 03 01 | 08 03 | 01 | 0F 01 | 00 47 | C5 6B | ||
1 | 4037 | – | 55 FF | 05 | – | 10 | 00 | 00 | 06 | E8 | 01 03 01 | 04 25 | 01 | – | – | B0 DD |
1449 | 55 FF | 06 | 00 | 10 | – | 00 | 0A | 76 | 02 03 01 | 04 25 | 01 | 0F 01 | 05 A9 | 0D 37 | ||
2 | 4037 | – | 55 FF | 05 | – | 11 | 00 | 00 | 06 | 61 | 01 03 01 | 04 25 | 01 | – | – | B0 DD |
1449 | 55 FF | 06 | 00 | 11 | – | 00 | 0A | EE | 02 03 01 | 04 25 | 01 | 0F 01 | 05 A9 | 0D 37 |
Set Requests¶
- Bytes 11 and 12 represent the parameter to be set
- Byte 13 is the instance, generally 01
Where the value/response is a float¶
- Request is 20 bytes long
- Response is 20 bytes long
- Byte 7 is 0A when the process value is a float
- When the process value is a float, the byte preceding the data (14) is 08
Addr. | Param | Process Val | Preamble | Req/Res | ?? | Zone | ?? | ?? | ?? | Chk | ?? | Param | Instance | ?? | Data | Data Chk |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 7001 | 392 | 55 FF | 5 | – | 10 | 0 | 0 | 0A | EC | 01 04 | 07 01 | 1 | 8 | 43 C4 00 00 | EB 77 |
392 | 55 FF | 6 | 0 | 10 | – | 0 | 0A | 76 | 02 04 | 07 01 | 1 | 8 | 43 C4 00 00 | 82 03 | ||
2 | 7001 | 392 | 55 FF | 5 | – | 11 | 0 | 0 | 0A | 65 | 01 04 | 07 01 | 1 | 8 | 43 C4 00 00 | EB 77 |
392 | 55 FF | 6 | 0 | 11 | – | 0 | 0A | EE | 02 04 | 07 01 | 1 | 8 | 43 C4 00 00 | 82 03 |
Where the value/response is an integer:¶
- Request is 19 bytes long
- Response is 19 bytes long
- Byte 7 is 09 when the process value is an integer
- When the process value is an integer, the two bytes preceeding the data (14, 15) are 0F 01
Addr. | Param | Process Val | Preamble | Req/Res | ?? | Zone | ?? | ?? | Msg Type? | Chk | ?? | Param | Instance | ?? | Data | Data Chk |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 8003 | 71 | 55 FF | 05 | – | 10 | 03 | 00 | 09 | 46 | 01 04 | 08 03 | 01 | 0F 01 | 00 47 | 8f ED |
71 | 55 FF | 06 | 03 | 10 | – | 00 | 09 | EF | 02 04 | 08 03 | 01 | 0F 01 | 00 47 | 88 3B |
Errors¶
Currently, it is unclear exactly what these responses mean, or what the structure of an error message is, but the following are possibly errors:
This is likely an access denied error response received when trying to write a read only parameter (4001, 100 degrees, address 2):
- 55 FF 06 00 11 00 02 17 02 80 FF B8
Other possible errors that have been received:
- 55 FF 06 00 10 00 02 8F 02 85 52 EF
- 55 FF 06 00 10 00 02 8F 02 86 C9 DD
- 55 FF 06 00 10 00 02 8F 02 83 64 8A
- 55 FF 06 00 10 00 02 8F 02 80 FF B8
- 55 FF 06 00 10 00 05 73 02 05 08 03 00 02 5B
- 55 FF 06 00 10 00 05 73 02 05 01 08 00 B4 23
Contributing¶
Contributions are welcome, and they are greatly appreciated! Every little bit helps, and credit will always be given.
Bug reports¶
When reporting a bug please include:
- Your operating system name and version.
- Any details about your local setup that might be helpful in troubleshooting.
- Detailed steps to reproduce the bug.
Documentation improvements¶
pywatlow could always use more documentation, whether as part of the official pywatlow docs, in docstrings, or even on the web in blog posts, articles, and such.
Feature requests and feedback¶
The best way to send feedback is to file an issue at https://github.com/BrendanSweeny/pywatlow/issues.
If you are proposing a feature:
- Explain in detail how it would work.
- Keep the scope as narrow as possible, to make it easier to implement.
- Remember that this is a volunteer-driven project, and that code contributions are welcome :)
Development¶
To set up pywatlow for local development:
Fork pywatlow (look for the “Fork” button).
Clone your fork locally:
git clone git@github.com:BrendanSweeny/pywatlow.git
Create a branch for local development:
git checkout -b name-of-your-bugfix-or-feature
Now you can make your changes locally.
When you’re done making changes run all the checks and docs builder with tox one command:
tox
Commit your changes and push your branch to GitHub:
git add . git commit -m "Your detailed description of your changes." git push origin name-of-your-bugfix-or-feature
Submit a pull request through the GitHub website.
Pull Request Guidelines¶
If you need some code review or feedback while you’re developing the code just make the pull request.
For merging, you should:
- Include passing tests (run
tox
) [1]. - Update documentation when there’s new API, functionality etc.
- Add a note to
CHANGELOG.rst
about the changes. - Add yourself to
AUTHORS.rst
.
[1] | If you don’t have all the necessary python versions available locally you can rely on Travis - it will run the tests for each change you add in the pull request. It will be slower though … |
Tips¶
To run a subset of tests:
tox -e envname -- pytest -k test_myfeature
To run all the test environments in parallel (you need to pip install detox
):
detox
Authors¶
- Brendan Sweeny - brendansweeny.com