A Python driver for the Watlow EZ-Zone PM temperature controller standard bus protocol

  • Free software: GNU Lesser General Public License v3 (LGPLv3)

Installation

pip install pywatlow

You can also install the in-development version with:

pip install https://github.com/BrendanSweeny/pywatlow/archive/master.zip

Development

To run the all tests run:

tox

Note, to combine the coverage data from all the tox environments run:

Windows
set PYTEST_ADDOPTS=--cov-append
tox
Other
PYTEST_ADDOPTS=--cov-append tox

Installation

At the command line:

pip install pywatlow

Usage

Command Line Usage

Format:

pywatlow [-h] [-r PORT ADDR PARAM | -s PORT ADDR TEMP]

Read the current temperature in degrees Celsius. This is equivalent to calling Watlow(port=’COM5’,address=1).read():

# Read the current temperature (parameter 4001) of the Watlow controller
# at address 1 (Watlow controller's default) on serial port COM5:
>>> pywatlow -r COM5 1 4001
{'address': 1, 'param': 4001, 'data': 50.5, 'error': None}

Read the setpoint temperature in degrees Celsius. This is equivalent to calling Watlow(port=’COM5’,address=1).readSetpoint():

# Read the setpoint (parameter 7001) of the Watlow controller
# at address 1 on serial port COM5:
>>> pywatlow -r COM5 1 7001
{'address': 1, 'data': 60.0, 'error': None}

Change the setpoint temperature (degrees Celsius). This is equivalent to calling Watlow(port=’COM5’,address=1).write(50):

# Change the setpoint of the Watlow controller
# at address 1 on serial port COM5:
>>> pywatlow -w COM5 1 60
{'address': 1, 'param': 7001, 'data': 60.0, 'error': None}

At this time, CLI usage only supports reading the current temperature and the current setpoint.

Module Usage

To use pywatlow in a project:

from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)
print(watlow.read())
print(watlow.readSetpoint())
print(watlow.write(55))

##### Returns #####
{'address': 1, 'param': 4001, 'data': 59.5, 'error': None}
{'address': 1, 'param': 7001, 'data': 60.0, 'error': None}
{'address': 1, 'param': 7001, 'data': 55.0, 'error': None}

Using multiple temperature controllers on a single USB to RS485 converter:

from pywatlow.watlow import Watlow
import serial

ser = serial.Serial()
ser.port = 'COM5'
ser.baudrate = 38400  # Default baudrate for Watlow controllers
ser.timeout = 0.5
ser.open()

watlow_one = Watlow(serial=ser, address=1)
watlow_two = Watlow(serial=ser, address=2)
print(watlow_one.read())
print(watlow_two.read())

##### Returns #####
{'address': 1, 'param': 4001, 'data': 50.5, 'error': None}
{'address': 2, 'param': 4001, 'data': 60.0, 'error': None}

Reading Other Parameters

See the Watlow user manual for more information about the different parameter IDs and their functions.

The messaging structure for Watlow temperature controllers is set up to return data as integers or floats depending on the nature of the data. Often, ints are used to represent a state, such as in parameter ID 8003, the control loop heat algorithm.

data_type is not optional. Passing the incorrect type to data_type may result in an error (e.g. watlow.readParam(7001, int)). To see which data type each parameter expects, see the Watlow user manual.

In some cases, specifying the wrong data type (e.g. watlow.readParam(8003, float)) will result in the instance of Watlow reading characters from a separate queued message if multiple controllers are being used on the same USB/RS485 port without any async handling.

Here, a returned value of 71 for parameter 8003 corresponds to the PID algorithm. We can read the state of 8003 like so:

from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)

# Read the current heat algorithm
print(watlow.readParam(8003, int))

# Errors:
# Here the incorrect data type is given
print(watlow.readParam(7001, int))

##### Returns #####
{'address': 1, 'param': 8003, 'data': 71, 'error': None}  # 71 --> PID algorithm

If the user wishes to avoid parameters altogether, basic functionality (read temp/setpoint and write temperature) can be achieved with wrapper functions read(), readSetpoint(), and write(), described above. Other parameters can be set at the controllers using the physical buttons and hardware menu.

Setting Other Parameters

watlow.writeParam() is used to write to specific Watlow parameters. The message structure required for the set request depends on the data type (int or float). pywatlow will build the message based on this data type, which can be specified by passing the type class (either int or float) to the data_type argument.

If instead of a PID algorithm we would like something relatively simple like an “on-off” algorithm, we can set the value of parameter 8003 to 64:

from pywatlow.watlow import Watlow
watlow = Watlow(port='COM5', address=1)

print(watlow.readParam(8003, int))
print(watlow.writeParam(8003, 64, int))
print(watlow.writeParam(8003, 71, int))

# Errors:
# Here the incorrect data type is given
print(watlow.writeParam(8003, 71, float))

##### Returns #####
{'address': 1, 'param': 8003, 'data': 71, 'error': None}  # 71 --> PID algorithm
{'address': 1, 'param': 8003, 'data': 64, 'error': None}  # 64 --> on/off algorithm
{'address': 1, 'param': 8003, 'data': 71, 'error': None}  # Back to 71, PID
# Error resulting from specifying the wrong data type:
{'address': 1, 'param': None, 'data': None, 'error': Exception('Received a message that could not be parsed from address 1')}

Error Handling

Errors are passed through using the ‘error’ key of the returned dictionary. Here there is no temperature controller at address 2:

print(watlow_one.read())
print(watlow_two.read())

##### Returns #####
{'address': 1, 'param': 4001, 'data': 55.0, 'error': None}
{'address': 2, 'param': None, 'data': None, 'error': Exception('Exception: No response at address 2')}

Reference

Watlow

class watlow.Watlow(serial=None, port=None, timeout=0.5, address=1)[source]

Object representing a Watlow PID temperature controller. This class facilitates the generation and parsing of BACnet TP/MS messages to and from Watlow temperature controllers.

  • serial: serial object (see pySerial’s serial.Serial class) or None
  • port (str): string representing the serial port or None
  • timeout (float): Read timeout value in seconds
  • address (int): Watlow controller address (found in the setup menu). Acceptable values are 1 through 16.

timeout and port are not necessary if a serial object was already passed with those arguments. The baudrate for Watlow temperature controllers is 38400 and hardcoded.

read()[source]

Reads the current temperature. This is a wrapper around readParam() and is equivalent to readParam(4001, float).

Returns a dict containing the response data, parameter ID, and address.

readParam(param, data_type)[source]

Takes a parameter and writes data to the watlow controller at object’s internal address. Using this function requires knowing the data type for the parameter (int or float). See the Watlow user manual for individual parameters and the Usage section of these docs.

  • param: a four digit integer corresponding to a Watlow parameter (e.g. 4001, 7001)
  • data_type: the Python type representing the data value type (i.e. int or float)

data_type is used to determine how many characters to read following the controller’s response. If int is passed when the data type should be float, it will not read the entire message and will throw an error. If float is passed when it should be int, it will timeout, possibly reading correctly. If multiple instances of Watlow() are using the same serial port for different controllers it will read too many characters. It is best to be completely sure which data type is being used by each parameter (int or float).

Returns a dict containing the response data, parameter ID, and address.

readSetpoint()[source]

Reads the current setpoint. This is a wrapper around readParam() and is equivalent to readParam(7001, float).

Returns a dict containing the response data, parameter ID, and address.

write(value)[source]

Changes the watlow temperature setpoint. Takes a value (in degrees F by default), builds request, writes to watlow, receives and returns response object.

  • value: an int or float representing the new target setpoint in degrees F by default

This is a wrapper around writeParam() and is equivalent to writeParam(7001, value, float).

Returns a dict containing the response data, parameter ID, and address.

writeParam(param, value, data_type)[source]

Changes the value of the passed watlow parameter ID. Using this function requires knowing the data type for the parameter (int or float). See the Watlow user manual for individual parameters and the Usage section of these docs.

  • value: an int or float representing the new target setpoint in degrees F by default
  • data_type: the Python type representing the data value type (i.e. int or float)

data_type is used to determine how the BACnet TP/MS message will be constructed and how many serial characters to read following the controller’s response.

Returns a dict containing the response data, parameter ID, and address.

Watlow Messaging Structure

The following is an incomplete understanding of the messaging structure that the Watlow temperature controllers use. Enough of the structure is understood for the driver to be functional, but the function of many of the bytes is unknown to the author(s).

General Message Structure:

  • BACnet MS/TP protocol
  • First two bytes of any message make up the preamble, and are always: 55 FF
  • Byte 3 seems to define the type of message (read/response)
  • Byte 4 of the request defines the zone (internal Watlow address)
  • The zone appears in byte 5 of the response
  • Byte 7 appears to define the type of request
  • Byte 8 is the header check byte (more info at reverseengineering.stackexchange.com)
  • Immediately following the parameter bytes is the instance. I have yet to encounter a situation where this is not 01
  • The final two bytes of any message are the data check bytes (more info at reverseengineering.stackexchange.com)

How to read the example message tables:

  • Addr.: The address used in the request and response
  • Param: The parameter being read/set
  • Process Val.: The value represented in the “Data” column of the response/request
  • The message begins with the column labeled “Preamble” and continues to the right
  • Sometimes the byte number is not the same in the response as the request (e.g. Zone), hence the “-“

Read Requests

  • Read requests seem to be 16 bytes long no matter the data type
  • Byte 7 is 06 for read requests
  • Bytes 12 and 13 represent the parameter to be read
  • Byte 14 is the instance, generally 01
Where the response is a float:
  • Request is 16 bytes long
  • Response is 21 bytes long
  • Response types appear to be defined by bytes 7
  • Note: The process value for 4001 is ~2500 in these examples because no probe is connected
Example Messages
Addr. Param Process Val Preamble Req/Res ?? Zone ?? ?? ?? Chk ?? Param Instance ?? Data Data Chk
1 4001 55 FF 05 10 00 00 06 E8 01 03 01 04 01 01 E3 99
    2529.6 55 FF 06 00 10 00 0B 88 02 03 01 04 01 01 08 45 1E 3C D4 A7 28
2 4001 55 FF 05 11 00 00 06 61 01 03 01 04 01 01 E3 99
    2528.7 55 FF 06 00 11 00 0B 10 02 03 01 04 01 01 08 45 1E 0C 06 9A 6B
1 4012 55 FF 05 10 00 00 06 E8 01 03 01 04 0C 01 9B 29
    0.0 55 FF 06 00 10 00 0B 88 02 03 01 04 0C 01 08 00 00 00 00 2D 64
2 4012 55 FF 05 11 00 00 06 61 01 03 01 04 0C 01 9B 29
    0.0 55 FF 06 00 11 00 0B 10 02 03 01 04 0C 01 08 00 00 00 00 2D 64
1 7001 55 FF 05 10 00 00 06 E8 01 03 01 07 01 01 87 76
    392.0 55 FF 06 00 10 00 0B 88 02 03 01 07 01 01 08 43 C4 00 00 33 9A
                                 
Where the response is an integer:
  • Request is 16 bytes long
  • Response is 20 bytes long
Example Messages
Addr. Param Process Val Preamble Req/Res ?? Zone ?? ?? ?? Chk ?? Param Instance ?? Data Data Chk
1 8003 55 FF 05 10 00 00 06 E8 01 03 01 08 03 01 F0 0F
    71 55 FF 06 00 10 00 0A 76 02 03 01 08 03 01 0F 01 00 47 C5 6B
2 8003 55 FF 05 11 00 00 06 61 01 03 01 08 03 01 F0 0F
    71 55 FF 06 00 11 00 0A EE 02 03 01 08 03 01 0F 01 00 47 C5 6B
1 4037 55 FF 05 10 00 00 06 E8 01 03 01 04 25 01 B0 DD
    1449 55 FF 06 00 10 00 0A 76 02 03 01 04 25 01 0F 01 05 A9 0D 37
2 4037 55 FF 05 11 00 00 06 61 01 03 01 04 25 01 B0 DD
    1449 55 FF 06 00 11 00 0A EE 02 03 01 04 25 01 0F 01 05 A9 0D 37

Set Requests

  • Bytes 11 and 12 represent the parameter to be set
  • Byte 13 is the instance, generally 01
Where the value/response is a float
  • Request is 20 bytes long
  • Response is 20 bytes long
  • Byte 7 is 0A when the process value is a float
  • When the process value is a float, the byte preceding the data (14) is 08
Example Messages
Addr. Param Process Val Preamble Req/Res ?? Zone ?? ?? ?? Chk ?? Param Instance ?? Data Data Chk
1 7001 392 55 FF 5 10 0 0 0A EC 01 04 07 01 1 8 43 C4 00 00 EB 77
    392 55 FF 6 0 10 0 0A 76 02 04 07 01 1 8 43 C4 00 00 82 03
2 7001 392 55 FF 5 11 0 0 0A 65 01 04 07 01 1 8 43 C4 00 00 EB 77
    392 55 FF 6 0 11 0 0A EE 02 04 07 01 1 8 43 C4 00 00 82 03
Where the value/response is an integer:
  • Request is 19 bytes long
  • Response is 19 bytes long
  • Byte 7 is 09 when the process value is an integer
  • When the process value is an integer, the two bytes preceeding the data (14, 15) are 0F 01
Example Messages
Addr. Param Process Val Preamble Req/Res ?? Zone ?? ?? Msg Type? Chk ?? Param Instance ?? Data Data Chk
1 8003 71 55 FF 05 10 03 00 09 46 01 04 08 03 01 0F 01 00 47 8f ED
    71 55 FF 06 03 10 00 09 EF 02 04 08 03 01 0F 01 00 47 88 3B
Errors

Currently, it is unclear exactly what these responses mean, or what the structure of an error message is, but the following are possibly errors:

This is likely an access denied error response received when trying to write a read only parameter (4001, 100 degrees, address 2):

  • 55 FF 06 00 11 00 02 17 02 80 FF B8

Other possible errors that have been received:

  • 55 FF 06 00 10 00 02 8F 02 85 52 EF
  • 55 FF 06 00 10 00 02 8F 02 86 C9 DD
  • 55 FF 06 00 10 00 02 8F 02 83 64 8A
  • 55 FF 06 00 10 00 02 8F 02 80 FF B8
  • 55 FF 06 00 10 00 05 73 02 05 08 03 00 02 5B
  • 55 FF 06 00 10 00 05 73 02 05 01 08 00 B4 23

Contributing

Contributions are welcome, and they are greatly appreciated! Every little bit helps, and credit will always be given.

Bug reports

When reporting a bug please include:

  • Your operating system name and version.
  • Any details about your local setup that might be helpful in troubleshooting.
  • Detailed steps to reproduce the bug.

Documentation improvements

pywatlow could always use more documentation, whether as part of the official pywatlow docs, in docstrings, or even on the web in blog posts, articles, and such.

Feature requests and feedback

The best way to send feedback is to file an issue at https://github.com/BrendanSweeny/pywatlow/issues.

If you are proposing a feature:

  • Explain in detail how it would work.
  • Keep the scope as narrow as possible, to make it easier to implement.
  • Remember that this is a volunteer-driven project, and that code contributions are welcome :)

Development

To set up pywatlow for local development:

  1. Fork pywatlow (look for the “Fork” button).

  2. Clone your fork locally:

    git clone git@github.com:BrendanSweeny/pywatlow.git
    
  3. Create a branch for local development:

    git checkout -b name-of-your-bugfix-or-feature
    

    Now you can make your changes locally.

  4. When you’re done making changes run all the checks and docs builder with tox one command:

    tox
    
  5. Commit your changes and push your branch to GitHub:

    git add .
    git commit -m "Your detailed description of your changes."
    git push origin name-of-your-bugfix-or-feature
    
  6. Submit a pull request through the GitHub website.

Pull Request Guidelines

If you need some code review or feedback while you’re developing the code just make the pull request.

For merging, you should:

  1. Include passing tests (run tox) [1].
  2. Update documentation when there’s new API, functionality etc.
  3. Add a note to CHANGELOG.rst about the changes.
  4. Add yourself to AUTHORS.rst.
[1]

If you don’t have all the necessary python versions available locally you can rely on Travis - it will run the tests for each change you add in the pull request.

It will be slower though …

Tips

To run a subset of tests:

tox -e envname -- pytest -k test_myfeature

To run all the test environments in parallel (you need to pip install detox):

detox

Authors

  • Brendan Sweeny - brendansweeny.com

Changelog

0.0.0 (2020-04-28)

  • First release on PyPI.

Indices and tables